4
Device settings
4.2
Device identification data
46
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2
Device identification data
0x2000 - Device: Data
0x2001 - Device: Name
4.3
Function "Optical device recognition"
0x2021 - Device: Optical recognition
Type code (Lenze ID), serial number and manufacturing date of the device
Sub.
Name
Lenze setting
Data type
1 Device: Product designation
STRING(50)
2 Device: Serial number
STRING(50)
3 Device: Manufacturing date
STRING(50)
Write access CINH OSC P RX TX
Any device name (e.g. "Wheel drive") can be set in this object for the purpose of device identification.
Write access CINH OSC P RX TX
STRING(128)
In the case of applications with multiple interconnected controllers, it may be difficult to locate a device that has
been connected online. The "Optical device recognition" function serves to locate the i700 servo inverter by means
of blinking LEDs.
• A setting of "1: Start" in subindex 1 activates the function:
• The two LEDs "RDY" and "ERR" on the front of the i700 servo inverter will blink for the time period set in
subindex 2 with a blinking frequency of 20 Hz. Then the function is deactivated automatically.
• The LEDs on the RJ45 sockets are not used for this function.
• If the function is reactivated within the time set, the time is extended correspondingly.
• With the setting "0: Stop" in subindex 1 the function can be aborted/deactivated prematurely.
Sub.
Name
Lenze setting
Data type
Start optical recognition
0: Stop
UNSIGNED_8
Optical recognition: Blinking time
5 s
UNSIGNED_16
Subindex 1:
Start optical recognition
Selection list
(Lenze setting printed in bold)
0 Stop
1 Start
Write access CINH OSC P RX TX
UNSIGNED_8
Subindex 2:
Optical recognition: Blinking time
Setting range
(min. value | unit | max. value)
Lenze setting
0
s
6000 5 s
Write access CINH OSC P RX TX
UNSIGNED_16