Monitoring functions
8.1
24-V supply voltage monitoring
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8
Monitoring functions
The i700 servo inverter is provided with various monitoring functions, which are described in the
following subchapters.
Objects described in this chapter
8.1
24-V supply voltage monitoring
The 24 V supply voltage is monitored by means of two specified voltage thresholds.
• The following table describes these thresholds and shows the device response resulting from
the level of the supply voltage:
Related topics:
Monitoring of the DC-bus voltage
Object
Name
Data type
Axis A
Axis B
Ixt utilisation
RECORD
Motor speed monitoring
RECORD
Motor phase failure detection
RECORD
Monitoring: Ultimate motor current
RECORD
Motor temperature monitoring: Parameter
RECORD
Motor utilisation (I²xt): Parameter for the thermal model
RECORD
Motor utilisation (I²xt): User-definable characteristic
RECORD
Motor utilisation (I²xt): Motor overload warning threshold
UNSIGNED_16
Motor utilisation (I²xt): Actual utilisation
UNSIGNED_32
Motor utilisation (I²xt): Motor overload error
UNSIGNED_32
Heatsink temperature
RECORD
Threshold
Voltage
Device response
U24 warn
21.45 V ±5 %
Above threshold: Normal operation
Below threshold: Normal operation with warning
U24 down
18.15 V ±5 %
Above threshold: Normal operation with warning
Below threshold: No operation
• Response with regard to the EtherCAT master and
adjacent EtherCAT slaves is undefined.