0x2d00, 0x3500, 7cia402 device profile – Lenze i700 User Manual
Page 230

7
CiA402 device profile
7.11
Touch probe (TP)
230
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Delay times of the digital inputs and required minimum signal lengths
The table below lists the delay times typical for the digital inputs of the i700 servo inverter and the
required minimum signal lengths:
0x2D00 | 0x3500 - Touch probe (TP): Dead time compensation
Digital signal
Typical delay time
Minimum signal length
Rising edge (HIGH pulse)
5 - 7 μs
7 μs
Falling edge (LOW pulse)
approx. 40 μs
50 μs
Delay time for the compensation of runtime delays (latencies)
• Set the sum of individual delays for each touch probe channel here (sensor, cable, and input connection).
Sub.
Name
Lenze setting
Data type
Dead time compensation: TP1 dead time
0.000 ms
UNSIGNED_16
Dead time compensation: TP2 dead time
0.000 ms
UNSIGNED_16
Subindex 1:
Dead time compensation: TP1 delay time
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
ms
7.000 0.000 ms
Write access CINH OSC P RX TX
Scaling: 1/1000
UNSIGNED_16
Subindex 2:
Dead time compensation: TP2 delay time
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
ms
7.000 0.000 ms
Write access CINH OSC P RX TX
Scaling: 1/1000
UNSIGNED_16