5
Motor control & motor settings
5.12
Fine adjustment des motor model
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7. Enter the Vp values in per cent from the grid points into the subindices of object
(or
for axis B):
[5-6]
Grid point values of the saturation characteristic determined
8. Enter the maximum process current ("15 A") as maximum current in object
for axis B).
• With these settings, the same current characteristic should occur, irrespective of the current
magnitude.
• Since the current controller gain is now corrected actively, the step responses may differ
slightly compared to the previous measurements. In this case, the current controller
parameters must be optimised one last time.
9. For permanent storage: Upload the detected characteristic from the i700 servo inverter into the
Controller.
The »EASY Starter« serves to save the parameter settings of the i700 servo inverter as parameter
file (*.gdc). In the »PLC Designer«, this file can then be imported in the corresponding axis.
Saving changed parameters safe against mains failure
Setting for grid points 1 ... 17 in [%]
y1
y2
y3
y4
y5
y6
y7
y8
y9
y10
y11
y12
y13
y14
y15
y16
y17
137 137
137
137
137
109
92
80
68
61
53
45
37
32
26
22
19
0
6.25
12.5
18.75
25
31.25
37.5
43.75
50
56.25
62.5
68.75
75
81.25
87.5
93.75
100
I
max
[%]
Vp [%]
0
109
x2
x3
x4
x5
x6
x7
x8
x9
x10
x11
x12
x13
x14
x15
x16
x1
19
137
x17
Vp = "3.8 V/A"
100 %
º
92
80
68