11 appendix, 1 table of attributes – Lenze i700 User Manual
Page 305

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
305
11
Appendix
11.1
Table of attributes
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Motor temperature monitoring: Parameter
1: Motor temperature monitoring: Sensor type
UNSIGNED_8
-
P
2: Motor temperature monitoring: Response
UNSIGNED_8
-
P
3: Motor temperature monitoring: Warning threshold
INTEGER_16
1/10
P
4: Motor temperature monitoring: Error threshold
INTEGER_16
1/10
P
5: Motor temperature monitoring: Actual motor temperature
INTEGER_16
1/10
OSC
Tx
6: Thermal sensor characteristic: Grid point 1 - temperature
INTEGER_16
1/10
P
7: Thermal sensor characteristic: Grid point 2 - temperature
INTEGER_16
1/10
P
8: Thermal sensor characteristic: grid point 1 - resistance
INTEGER_16
-
P
9: Thermal sensor characteristic: grid point 2 - resistance
INTEGER_16
-
P
Motor utilisation (I²xt): Parameter for the thermal model
1: Motor utilisation (I²xt): Thermal time constant - winding
UNSIGNED_16
-
P
2: Motor utilisation (I²xt): Thermal time constant - laminations
UNSIGNED_16
-
P
3: Motor utilisation (I²xt): Influence of the winding
UNSIGNED_8
-
P
4: Motor utilisation (I²xt): Starting value
UNSIGNED_16
-
P
Motor utilisation (I²xt): User-definable characteristic
1: I²xt: x1 = n01/nN (n01 ~ 0)
UNSIGNED_16
-
P
2: I²xt: y1 = i01/iN (x = n01 ~ 0)
UNSIGNED_16
-
P
3: I²xt: x2 = n02/nN (n02 = limit - reduced cooling)
UNSIGNED_16
-
P
4: I²xt: y2 = i02/iN (x = n02 = limit - reduced cooling)
UNSIGNED_16
-
P
5: I²xt: x3 = n03/nN (n03 = rated speed)
UNSIGNED_16
-
P
6: I²xt: y3 = i03/iN (x = n03 = rated speed)
UNSIGNED_16
-
P
7: I²xt: x4 = n04/nN (n04 = limit - field weakening)
UNSIGNED_16
-
P
8: I²xt: y4 = i04/iN (x = n04 = limit - field weakening)
UNSIGNED_16
-
P
Motor utilisation (I²xt): Motor overload warning threshold
UNSIGNED_16
-
P
Motor utilisation (I²xt): Actual utilisation
UNSIGNED_16
-
OSC
Tx
Motor utilisation (I²xt): Motor overload error
1: Motor utilisation (I²xt): Response
UNSIGNED_8
-
P
2: Motor utilisation (I²xt): Error threshold
UNSIGNED_16
-
P
Counter: Operating time
1: Device: Operating time
UNSIGNED_32
-
2: Device: Power-on time
UNSIGNED_32
-
Motor: Actual voltage - Veff, phase-phase
UNSIGNED_32
1/10
OSC
Tx
Motor: Phase currents
1: Zero system current
INTEGER_32
1/100
OSC
Tx
2: Current - phase U
INTEGER_32
1/100
OSC
Tx
3: Current - phase V
INTEGER_32
1/100
OSC
Tx
4: Current - phase W
INTEGER_32
1/100
OSC
Tx
Heatsink temperature
1: Heatsink temperature: Actual temperature
INTEGER_16
1/10
OSC
2: Heatsink temperature: Warning threshold
INTEGER_16
1/10
P
3: Heatsink temperature: Threshold - switch-on fan
INTEGER_16
1/10
P
4: Heatsink temperature: Threshold - switch-off fan
INTEGER_16
1/10
P
Speed monitoring: Actual speed error
INTEGER_32
-
OSC
Tx
Field: Values
1: Field: Actual field
UNSIGNED_16
-
OSC
Tx
2: Field: Setpoint field
UNSIGNED_16
-
OSC
Tx
Index
Name
Data type
Scaling
Attributes
Greyed out = read only