1 shutdown, Shutdown, 7cia402 device profile – Lenze i700 User Manual
Page 172
![background image](/manuals/566307/172/background.png)
7
CiA402 device profile
7.4
Device control
172
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.1.1
Shutdown
From all states
Power section inhibited (pulse inhibit)
Power section enabled
This command changes the device status from
"
" to "
If the pulse inhibit has already been
deactivated and the device status of the
controller is "
", this
command can be used to set the pulse inhibit
again.
• If automatic brake operation is activated,
the parameterised brake closing time is
observed: The system waits until the brake
is applied before the pulse inhibit is set.
• The motor becomes torqueless.
• The device status "
" or
" changes back to
".
Danger!
If the motor gets torqueless and a load is
connected, motors without a holding brake
may move in an uncontrolled way!
In case no load is connected, the motor is
coasting.
Bit pattern for the "Shutdown" command in the Controlword (
for axis B):
Bits 15 - 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Fault reset
Control bits depending on the operating mode
Enable
operation
Activate quick
stop
Enable voltage
Switch on
X
0
X
X
X
X
1
1
0
1
2
0
Ready to
switch on
Not ready to
switch on
Switched
on
Operation
enabled
Fault reaction
active
Fault
Switch-on
disabled
Quick stop
active
Power-on