Lenze i700 User Manual
Page 5
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
5
Contents
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Jerk limitation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2945 | 0x3145 - Torque: Setpoint jerk limitation
Notch filters (band-stop filters) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2944 | 0x3144 - Torque: Notch filter setpoint torque
Defining the V/f characteristic shape _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B00 | 0x3300 - VFC: V/f characteristic - shape
0x2B01 | 0x3301 - VFC: V/f characteristic - define reference point
0x2B02 | 0x3302 - VFC: User-definable V/f characteristic - frequency grid points (x)
0x2B03 | 0x3303 - VFC: User-definable V/f characteristic - voltage grid points (y)
Activating the voltage vector control (lmin controller) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Setting the voltage boost _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B06 | 0x3306 - VFC: Voltage boost
Setting the load adjustment _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B07 | 0x3307 - VFC: Load adjustment parameter
Defining the behaviour at the current limit (Imax controller) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B08 | 0x3308 - VFC: Imax controller - Parameter
Setting the slip compensation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B09 | 0x3309 - VFC: Slip compensation - Parameter
Setting the oscillation damping _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B0A | 0x330A - VFC: Oscillation damping - Parameter
Optimising pull-out slip limitation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B0C | 0x330C - VFC: Override point of field weakening
Display parameter _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B0B | 0x330B - VFC: Setpoint frequency
0x2BA0 | 0x33A0 - Flying restart: Activate
0x2BA1 | 0x33A1 - Flying restart: Current
0x2BA2 | 0x33A2 - Flying restart: Start frequency
0x2BA3 | 0x33A3 - Flying restart: Integration time
0x2BA4 | 0x33A4 - Flying restart: Min. deviation
0x2BA5 | 0x33A5 - Flying restart: Delay time
0x2BA6 | 0x33A6 - Flying restart: Result
0x2B80 | 0x3380 - DC-injection braking: Current
0x2939 | 0x3139 - Switching frequency
6
Holding brake control _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
157
Triggering via control word via external control (Lenze setting) _ _ _ _ _ _ _ _ _ _ _ _ _ _
Triggering via state machine of device _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
No brake connected _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _