CiA402 device profile
7.10
Cyclic sync torque mode (cst)
220
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2946 | 0x3146 - Cyclic sync torque mode: Speed limitation
0x6071 | 0x6871 - Torque demand
0x6072 | 0x6872 - Max torque
The torque control contains a speed limitation as a protective function against very high speeds. High speeds can
occur in the case of a mere torque selection if no counter-torque is available (load-free machine).
The speed limitation function takes effect if the actual motor speed reaches the limit values set here: The motor
speed is kept at the limit value in each case. If the machine is decelerated by a counter-torque again, the speed
limitation hands control back to the external setpoint via the setpoint torque.
Note!
The upper limit value must be set to a greater value than the lower limit value. There is no plausibility check in the
i700 servo inverter.
Sub.
Name
Lenze setting
Data type
Speed limitation: Upper speed limit
0 [n-unit]
INTEGER_32
Speed limitation: Lower speed limit
0 [n-unit]
INTEGER_32
Subindex 1:
Speed limitation: Upper speed limit
Upper limit for the speed limitation
Setting range
(min. value | unit | max. value)
Lenze setting
-480000
[n unit]
480000 0 [n-unit]
Write access CINH OSC P RX TX
Scaling: 480000/2
31
INTEGER_32
Subindex 2:
Speed limitation: Lower speed limit
Lower limit for the speed limitation
Setting range
(min. value | unit | max. value)
Lenze setting
-480000
[n unit]
480000 0 [n-unit]
Write access CINH OSC P RX TX
Scaling: 480000/2
31
INTEGER_32
Target torque or torque feedforward control
• 100 % ≡ rated motor torque (
or
for axis B)
Setting range
(min. value | unit | max. value)
Lenze setting
-3276.8
%
3276.7 0.0 %
Write access CINH OSC P RX TX
Scaling: 1/10
INTEGER_16
Symmetrical selection of the maximum permissible torque
• 100 % ≡ rated motor torque (
or
for axis B)
• This parameter serves to implement a statically and bipolarly acting torque limitation. This can be used, for
instance, as overload protection of the mechanical transmission path/elements starting at the motor shaft.
• This limitation acts independently of the unipolarly acting torque limitations which act as process data on the
objects
for axis B) and
for axis B). For details see
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
%
3276.7 250.0 %
Write access CINH OSC P RX TX
Scaling: 1/10