6 setting the slip compensation, Setting the slip compensation, 0x2b09 – Lenze i700 User Manual
Page 145: 0x3309, 5motor control & motor settings

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
145
5
Motor control & motor settings
5.14
Parameterising the V/f characteristic control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.14.6
Setting the slip compensation
The slip compensation serves to automatically compensate a load-dependent speed loss. In order
that the slip compensation can operate correctly, the rated slip of the motor is required. It is
calculated from the rated motor frequency and the rated motor speed, thus both parameters must
be parameterised correctly.
0x2B09 | 0x3309 - VFC: Slip compensation - Parameter
Sub.
Name
Lenze setting
Data type
VFC: Slip compensation - influence
0.00 %
INTEGER_16
VFC: Slip compensation - filter time
2000 ms
UNSIGNED_16
Subindex 1:
VFC: Slip compensation - influence
Adjustment in percent of the slip calculated
• For instance required for deviations of the real motor data from the nameplate data.
• A setting of 100 % corresponds to the rated slip of the machine.
Setting range
(min. value | unit | max. value)
Lenze setting
-200.00
%
200.00 0.00 %
Write access CINH OSC P RX TX
Scaling: 1/100
INTEGER_16
Subindex 2:
VFC: Slip compensation - filter time
Adjustment of the time-dependent behaviour of the slip compensation
Setting range
(min. value | unit | max. value)
Lenze setting
1
ms
6000 2000 ms
Write access CINH OSC P RX TX
UNSIGNED_16