0x29E1 | 0x31E1 - field: Field set value limitation
0x29E2 | 0x31E2 - DC link circuit voltage: Filter time
0x29E3 | 0x31E3 - motor: Actual voltage - filter time
0x29E4 | 0x31E4 - Voltage reserve range
Subindex 2:
Field weakening controller: Reset time
Setting range
(min. value | unit | max. value)
Lenze setting
1.0
ms
240000.0 2000.0 ms
Write access CINH OSC P RX TX
Scaling: 1/10
UNSIGNED_32
Setting range
(min. value | unit | max. value)
Lenze setting
5.00
%
100.00 100.00 %
Write access CINH OSC P RX TX
Scaling: 1/100
UNSIGNED_16
Setting range
(min. value | unit | max. value)
Lenze setting
1.0
ms
1000.0 25.0 ms
Write access CINH OSC P RX TX
Scaling: 1/10
UNSIGNED_16
Setting range
(min. value | unit | max. value)
Lenze setting
1.0
ms
1000.0 25.0 ms
Write access CINH OSC P RX TX
Scaling: 1/10
UNSIGNED_16
From version 01.03
Voltage reserve range at the transition point to the field weakening
• Only relevant for servo control for asynchronous motor (selection "2" in
or
for axis B).
Setting range
(min. value | unit | max. value)
Lenze setting
1
%
20 5 %
Write access CINH OSC P RX TX
UNSIGNED_8