2 device protection by current derating, Device protection by current derating, Technical data – Lenze ECSCPxxx User Manual
Page 37

Technical data
Current characteristics
Device protection by current derating
l
37
EDBCSXP064 EN 8.0
3.3.2
Device protection by current derating
The maximum output current is limited. With output frequencies < 5 Hz the limitation
depends on the heatsink temperature.
0.75
1.00
0.57
0.38
0.67
0.00
1.00
0
5
10
fout [Hz]
Iout
Imax
≤ 70 °C
90 °C
ECSXA024
Fig. 3−2
Current derating characteristics
Operation with switching frequency = 8 kHz (C0018 = 1).
l
If the current exceeds the characteristic
, the switching frequency is automatically
changed to 4 kHz (e.g. for higher torque in acceleration processes).
Operation with switching frequency = 4 kHz (C0018 = 0).
l
The current limitation follows the characteristic
.
l
With output frequencies < 5 Hz and heatsink temperatures between 70 and 90 °C the
current limit is steplessly adjusted in the range
.
Type
I
max
[A]
Switching frequency 8 kHz
Switching frequency 4 kHz
f
out
> 5 Hz
f
out
W 0 Hz
f
out
> 5 Hz
f
out
W 0 Hz
£ 70 °C
f
out
W 0 Hz
90 °C
ECSxP004
2.7
1.5
4.0
3.0
2.3
ECSxP008
5.3
3.0
8.0
6.0
4.6
ECSxP016
10.7
6.0
16.0
12.0
9.1
ECSxP032
21.3
12.1
32.0
24.0
18.1
ECSxP048
32.0
18.1
48.0
36.3
27.2
ECSxP064
42.7
24.2
64.0
48.0
36.3