Appendix – Lenze ECSCPxxx User Manual
Page 382

Appendix
Code table
l
382
EDBCSXP064 EN 8.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0605 MONIT OH5
2
Fault response − monitoring of
temperature inside the
controller.
Temperature threshold can be
set under C0124.
^ 304
0
TRIP
2
Warning
3
Off
C0606 MONIT OC8
2
Fault response − monitoring of
I
2
x t motor utilisation.
Threshold can be set under
C0120.
^ 309
0
TRIP
2
Warning
3
Off
C0607 MONIT NMAX
0
Fault response − maximum speed
monitoring of the machine
0
TRIP
2
Warning
3
Off
C0608 ovr. Tx−Queue
2
Fault response − transmission
memory overflow of free CAN
objects
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C0609 ovr. Rx−Isr
0
Fault response Receive memory
overflow of free CAN objects
0
TRIP
4
FAIL−QSP
C0855
Digital process data input words
are indicated on the AIF interface
(AIF1_IN)
Hexadecimal value is bit−coded.
Read only
1 AIF1 IN bits
0000
{hex}
FFFF Input word 2 (bit 0 ... 15)
2 AIF1 IN bits
Input word 3 (bit 0 ... 15)
C0856
Analog process data input words
are indicated decimally on the
AIF interface (AIF1_IN)
100.00% = 16384
Read only
1 AIF1 IN words
−199.99
{0.01 %}
199.99 Input word 1
2 AIF1 IN words
Input word 2
3 AIF1 IN words
Input word 3
C0857 AIF1 IN phi
32 bits of phase information on
the AIF interface (AIF1_IN)
Read only
−2147483648
{1}
2147483647