Commissioning
Setting the positioning profile
Activating the speed override
l
207
EDBCSXP064 EN 8.0
Override−AIN and override−PDO are activated simultaneously
If override−AIN and override−PDO are activated at the same time, both override inputs are
effective (also for direct positioning).
ƒ
Setting: C3096/x.Bit0 = 1 (xxxx.xxxx.xxxx.xxx1) und C3096/x.Bit3 = 1
(xxxx.xxxx.xxxx.1xxx)
Example: Calculation of the effective speed (v
real
)
ƒ
Profile traversing speed (v
prof
) = 5000 mm/s
ƒ
Override−AIN = 80 %
ƒ
Override−PDO = 50 %
v
real
+ v
prof
@ Override−AIN [%] @ Override−PDO [%]
5000 mm
ńs @ 80 % @ 50 % + 2000 mmńs
The speed override is deactivated under the following conditions (is a byword for override
= 100 %):
ƒ
C3096/x.Bit0= 0 (xxxx.xxxx.xxxx.xxx0) bzw. Bit3 = 0 (xxxx.xxxx.xxxx.0xxx)
ƒ
Operating status "Trouble" is active.
ƒ
Operating status "Stand−by" is active.
(For information on operating states see