Installing of the standard device – Lenze EVS9332xK User Manual
Page 69
Installing of the standard device
Standard devices with a power of 45 kW
Modification of the fan module for push−through technique
4.3
4.3.4
l
4.3−5
EDSVS9332K EN 8.0−07/2013
9300vec173
Fig. 4.3−5
Plugging the fan connecting cable for the voltage supply to another terminal
1. Remove the cable lugs of the two red connecting cables and plug them
in again on the diagonally arranged side.
2. Remove the cable lugs of the two blue connecting cables and plug
them in again on the diagonally arranged side.
9300vec172
Fig. 4.3−6
Mounting the fan module on the controller
1. Place the fan module onto the controller. Insert the lugs at the back
into the base plate
0.
Make sure that the threaded sleeves do not touch the housing edge. They
may break off.
2. Push the fan module to the front.
3. Screw−in and fasten the 4 screws for fixing the fan module on each
side.
4. Screw−in and fasten the two screws for the supply voltage.
Plugging the fan connecting
cable to another terminal on
the fan module
Mounting the fan module in a
manner rotated by 180°