Configuration – Lenze EVS9332xK User Manual
Page 315

Configuration
Code table
8.4
l
8.4−41
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0878
g
DCTRL
Display of digital input signals
1 (C0870/1)
2 (C0870/2)
3 (C0871)
4 (C0876)
C0879
0
1
No reset
Reset
Reset control words
1 RESET C135
0
2 RESET AIF
0
3 RESET CAN
0
C0885
s
R
51
DIGIN1
® Selection list 2 R/L/Q
Configuration of digital input signal (CW
rotation)
C0886
s
L
52
DIGIN2
® Selection list 2 R/L/Q
Configuration of digital input signal (CCW
rotation)
C0889
g
R/L/Q
Display of digital input signals
1 (C0885)
2 (C0886)
C0890
s
N−SET
5050 NSET−NOUT
® Selection list 1 MCTRL
Configuration of input signal for speed
setpoint
C0891
s
M−ADD
1000 FIXED0%
® Selection list 1 MCTRL
Configuration of input signal for torque
setpoint
C0892
s
LO−M−LIM
5700 ANEG1−OUT
® Selection list 1 MCTRL
Configuration of input signal for lower torque
limit
C0893
s
HI−M−LIM
19523 FCODE−472/3
® Selection list 1 MCTRL
Configuration of input signal for upper
torque limit
C0894
s
PHI−SET
1000 FIXED0INC
® Selection list 3 MCTRL
Configuration of input signal for rotor
position setpoint
C0895
s
PHI−LIM
1006 FIXED100%
® Selection list 1 MCTRL
Configuration of input signal for phase
controller limit
C0896
s
N2−LIM
1000 FIXED0%
® Selection list 1 MCTRL
Configuration of input signal for 2nd speed
limit value
C0897
s
PHI−ON
1000 FIXED0
® Selection list 2 MCTRL
Configuration of phase controller switch−on
signal
C0898
s
FLD−WEAK
1006 FIXED100%
® Selection list 1 MCTRL
Configuration of input signal for field
weakening
C0899
s
N/M−SWT
1000 FIXED0
® Selection list 2 MCTRL
Configuration of input signal for changeover
between speed and torque control
C0900
s
QSP
10250 R/L/Q−QSP
® Selection list 2 MCTRL
Configuration of control signal for release
C0901
s
I−SET
1000 FIXED0%
® Selection list 1 MCTRL
Configuration of input signal for loading
I−component of speed controller