Configuration – Lenze EVS9332xK User Manual
Page 334
Configuration
Code table
8.4
l
8.4−60
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C1322
s
® Selection list 2 CDATA, CURVEC1
Configuration of digital input signals
1 CDATA−CYCLE
1000 FIXED0
HIGH = Profiles under C1311 and C1312 are
processed cyclically.
2 CDATA−RESET
1000 FIXED0
HIGH: If CDATA−CYCLE = LOW, the input
CDATA−SEL is immediately evaluated; if
CDATA−CYCLE = HIGH, the profile under
C1311 is processed.
3 CDATA−REL−SEL
1000 FIXED0
HIGH: Feed function active
4 CDATA−XRESET
1000 FIXED0
HIGH: Sets master value integrator to 0
5 CDATA−X−TP
1000 FIXED0
HIGH: Sets master value integrator to TP−POS
if input X−TP/E5 = LOW
6 CDATA−HOLD
1000 FIXED0
HIGH: Inhibits profile switching, input has
priority
7 CDATA−LOAD
1000 FIXED0
LOW/HIGH edge activates reloaded/new
profiles
8 CDATA−X−TP/E
5
1000 FIXED0
Selection of TP initiator:
LOW= Initiator at X−TP
HIGH = Connect initiator to terminal X5/E5
9 CURVEC1−HOL
D
1000 FIXED0
HIGH = Outputs AOUT and OUT are stored;
DFOUT = 0
10 CURVEC1−SEL−I
N
1000 FIXED0
Selection − input AIN
«IN
LOW = AIN
HIGH = IN
11 CURVEC1−REL−S
EL
1000 FIXED0
HIGH: feed function active (relative
positioning)
12 CURVEC1−XRES
ET
1000 FIXED0
HIGH: sets the master value integrator to the
value at input CDATA−X−START
13 CDATA−TEACH
1000 FIXED0
HIGH: Teach function is activated
l
Contact Lenze
14 CDATA−TP−DISA
BLE
1000 FIXED0
HIGH: No evaluation of the touch−probe
signals
15 CDATA−SEL−CA
M−MODE
1000 FIXED0
Mode for changing−over between profiles:
l
LOW: During operation, change−over
between profiles takes place at the end of
a profile
l
HIGH: Change−over between profiles can
take place while a motion profile is being
processed
– Only possible with the absolute data
model
– The interpolation points must have an
absolutely equal distribution
– The motion profiles must be congruent
at the point of change−over
– The change−over takes place
immediately when a new profile
number is selected
16 CDATA−TP−EDG
E−SELECT
1000 FIXED0
HIGH: The LOW/HIGH edge of the
touch−probe signal is evaluated
LOW: The HIGH/LOW edge of the
touch−probe signal is evaluated
C1323
g
CDATA, CURVEC1
Display of digital input signals
1 (C1322/1)
... ...