Configuration – Lenze EVS9332xK User Manual
Page 305

Configuration
Code table
8.4
l
8.4−31
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0725 FUNCTION
2
0
1
2
On delay
Off delay
On/off delay
DIGDEL2
Function selection
C0726 DELAY T
1.000 0.001
{0.001 s}
60.000 DIGDEL2
Setting of the delay time
C0728
s
IN
1000 FIXED0
® Selection list 2 DIGDEL2
Configuration of digital input signal
C0729 (C0728)
g
DIGDEL2
Display of digital input signal
C0730 OSZ MODUS
0
0
1
Start measurement
Stop measurement
OSZ
Start/stop of measured value recording
C0731 OSZ STATUS
0
0
1
2
3
4
5
Measurement completed
Measurement active
Trigger detected
Cancel
Cancel after trigger
Read memory
OSZ
Current operating state
C0732
s
® Selection list 1 OSZ
Configuration of analog input signals
1 KANAL1
1000 FIXED0%
2 KANAL2
1000 FIXED0%
3 KANAL3
1000 FIXED0%
4 KANAL4
1000 FIXED0%
C0733
® Selection list 2 OSZ
Trigger input
1 TRIG INP
1000 FIXED0
C0734 TRIG−SOURCE
1
0
1
2
3
4
Digital trigger input
Measuring channel 1
Measuring channel 2
Measuring channel 3
Measuring channel 4
OSZ
Selection of trigger source
C0735 TRIGGER−LEVEL
0
−32767
{1}
32767 OSZ
Adjustment of the trigger level for channel 1
... 4
C0736 TRIGGER−SLOPE
0
0
1
LOW/HIGH edge
HIGH/LOW edge
OSZ
Selection of the trigger edge
C0737 TRIGGER−DELA
Y
0.0
−100.0
{0.1 %}
999.9 OSZ
Setting of pretriggering and posttriggering
C0738 PROBE PERIOD
3
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
1 s
2 s
5 s
10 s
20 s
50 s
1 min
2 min
5 min
10 min
OSZ
Selection of the sampling period