Configuration, Code table – Lenze EVS9332xK User Manual
Page 286

Configuration
Code table
8.4
l
8.4−12
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0183 DIAGNOSTICS
g
Drive diagnostics
l
Indicates fault or status information
l
If several fault or status information units
are active simultaneously, the information
unit with the smallest number is displayed
0
OK
No fault
91
TRIP set C0135
TRIP via LECOM−A/B/LI or keypad
92
Trip−Set AIF
TRIP via AIF
93
Trip set CAN
TRIP via CAN
101
Initialisation
Initialisation phase
102
TRIP/fault
TRIP active
103
Emergency stop
Emergency stop has been executed
104
Pulse inhibit message
Message active
105
Power OFF
Function is not supported
111
Operation inhibit−C135
Operation inhibited
112
Operation inhibit−AIF
113
Operation inhibit−CAN
121
Controller inhibit, terminal 28
Controller inhibited via X5/28
122
Controller inhibit, internal 1
DCTRL−CINH1
123
Controller inhibit, internal 2
DCTRL−CINH2
124
Controller inhibit−C135/STOP
STOP key at the keypad
125
Controller inhibit−AIF
Controller inhibited via AIF
126
Controller inhibit−CAN
Controller inhibited via system bus
141
Switch−on inhibit
Restart protection active
142
Pulse inhibit
High−resistance power outputs
151
QSP−terminal, external quick stop
Quick stop via MCTRL−QSP
152
QSP−C135 quick stop
Quick stop via STOP key of the keypad
153
QSP−AIF quick stop
Quick stop via AIF
154
QSP−CAN quick stop
Quick stop via system bus
250
Warning C168
Warning active
C0190 NSET ARIT
0
0
1
2
3
4
5
OUT = C46
C46 + C49
C46 − C49
C46 * C49
C46 / C49
C46/(100 − C49)
NSET
Arithmetic block in the function block NSET
Connects main setpoint C0046 and additional
setpoint C0040
C0195 BRK1 T ACT
99.9
0.0
{0.1 s}
99.9 BRK1 brake engagement time
Engagement time of the mechanical holding
brake
l
After the time under C0195 has elapsed,
the status "mechanical brake closed" is
reached
C0196 BRK T RELEASE
0.0
0.0
{0.1 s}
60.0 BRK1 brake disengagement time
Disengagement time of the mechanical
holding brake (see technical data of the
brake).
l
After the time under C0196 has elapsed,
the status "mechanical brake open" is
reached
C0200 S/W ID
g
Software ID
Software identification
C0201 S/W DATE
g
Software release
Date of software release