Configuration
Code table
8.4
l
8.4−80
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C1718
s
® Selection list 1 STORE3
Configuration of analog input signals
1 STORE3−OFFSE
T
1000 FIXED0%
Selects the memory location the content of
which is to be output
2 STORE3−FREE
1000 FIXED0%
Reserved
C1719
g
STORE3
Configuration of analog input signals
1 (C1718/1)
2 (C1718/2)
C1720
s
® Selection list 2 STORE3
Configuration of digital input signals
1 STORE3−INIT
1000 FIXED0
Initialisation of all memory locations with the
value applied to STORE3−INIT−POS. The input
has the highest priority.
l
LOW/HIGH edge: Starts the initialisation
of all memory locations. The handshake
signals at STORE3−BUSY and STORE3−RDY
indicate the status of the initialisation.
l
LOW: sets STORE3−RDY = 0
l
HIGH: inhibits all other functions
2 STORE3−LOAD−I
N−POS
1000 FIXED0
l
LOW/HIGH edge: Transfers the value at
STORE3−IN−POS to the memory location
STORE3−SEL−IN
3 STORE3−STORE−
PHOUT
1000 FIXED0
STORE3−MODE = LOW:
l
LOW/HIGH edge: Transfers the content of
memory location STORE3−SEL−OUT to
STORE3−PHOUT
STORE3−MODE = HIGH:
l
Input inactive
4 STORE3−MODE
1000 FIXED0
l
LOW: The data of memory location
STORE3−SEL−OUT is output to
STORE3−STORE−PHOUT.
l
HIGH: The memory location to be output
to STORE3−PHOUT is calculated from
STORE3−SEL−IN ˘ STORE3−OFFSET. The
output is continuous.
C1721
g
STORE3
Display of digital input signals
1 (C1720/1)
... ...
4 (C1720/4)
C1722
s
® Selection list 3 STORE3
Configuration of input signals
1 STORE3−INIT−P
OS
1000 FIXED0INC
Value for initialising all memory locations.
l
The initialisation is started by a
LOW/HIGH edge at STORE3−INIT.
2 STORE3−IN−POS
1000 FIXED0INC
Value to be transferred to the memory
location selected with STORE3−SEL−IN.
l
The value is transferred with a LOW/HIGH
edge at STORE3−INIT.
C1723
g
{1 inc}
STORE3
Display of input signals
1 (C1722/1)
2 (C1722/2)