Configuration, Code table – Lenze EVS9332xK User Manual
Page 299
Configuration
Code table
8.4
l
8.4−25
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0560 FIX SET−VALUE
−199.99
{0.01 %}
199.99 Fixed setpoints
1
100
2
75
3
50
4
25
5
0
...
...
15
0
C0561
s
AIN
1000 FIXED0%
® Selection list 1 FIXSET1
Configuration of analog input signal
C0562
s
® Selection list 2 FIXSET1
Configuration of digital input signals
1 IN1
1000 FIXED0
2 IN2
1000 FIXED0
3 IN3
1000 FIXED0
4 IN4
1000 FIXED0
C0563 (C0561)
g −199.99
{0.01 %}
199.99 FIXSET1
Display of analog input signal
C0564
g
FIXSET1
Display of digital input signals
1 (C0562/1)
... ...
4 (C0562/4)
C0570
s
IN
1000 FIXED0%
® Selection list 1 S&H1
Configuration of analog input signal
C0571
s
LOAD
1000 FIXED0
® Selection list 2 S&H1 LOAD
Configuration of digital input signal
C0572 (C0570)
g −199.99
{0.01 %}
199.99 S&H1
Display of analog input signal
C0573 (C0571)
g
S&H1 LOAD
Display of digital input signal
C0575
1
0
{1 ms}
200 SD8 monitoring
Tripping delay for error message SD8
C0576
100.0
0
0.00
{0.01 %}
100.00 Speed window − nErr−monitoring
Setting the system deviation between actual
speed value and speed setpoint
C0577 VP FLD WEAK
3.00
0.00
{0.01}
15.99 Field weakening controller
Gain V
p
C0578 TN FLD WEAK
50.0
2.0
{0.5 ms}
8192.0 Field weakening controller
Reset time T
n
C0578 = 8000 ms: Switched off
C0579 MONIT NERR
3
0
1
2
3
Trip
Message
Warning
Off
nEEr monitoring
Configuration of monitoring for "system
deviation between actual speed value and
speed setpoint"
C0580 MONIT SD8
3
0
3
Trip
Off
SD8 monitoring
Configuration of monitoring for encoder error
at X8
C0581 MONIT EER
0
0
1
2
3
Trip
Message
Warning
Off
EEr monitoring
Configuration of monitoring for "external
fault"