Code table, Configuration – Lenze EVS9332xK User Manual
Page 275
Configuration
Code table
8.4
l
8.4−1
EDSVS9332K EN 8.0−07/2013
8.4
Code table
How to read the code table
Column
Abbreviation
Meaning
Code
Cxxxx
Code Cxxxx
l
Parameter value of the code can be defined
differently for each parameter set
l
Parameter value is accepted immediately (ONLINE)
1
Subcode 1 of Cxxxx
2
Subcode 2 of Cxxxx
v
Changed parameter of code or subcode is accepted after pressing
T V
s
Changed parameter of code or subcode is accepted after pressing
T V when
the controller is inhibited
Designation
Designation of the code
Lenze
Lenze setting (value at delivery or after restoring the delivery status with C0002)
à
The column "IMPORTANT" contains additional information
g
The code only displays a value. It cannot be configured.
Selection
1
{%}
99 Min. value
{unit}
max. value
IMPORTANT
−
Short, important explanation
Code
Possible settings
IMPORTANT
No.
Designation
Lenze Selection
C0002
s
PAR LOAD
0
Load parameter set
0
Default setting
Restore delivery status
1
Load parameter set 1
Load and activate the parameter set stored in
the controller
l
Parameter set 1 is loaded automatically
after every mains connection.
11
Load parameter set externally
Load parameter set from the keypad into the
controller
C0003 PAR SAVE
0
Save parameter set
0
Done
Saving completed
1
Save parameter set 1
Save the parameters loaded into the
controller in the parameter set
C0004 OP DISPLAY
56
0
{1}
1999 Operating display
Keypad shows selected code in the operating
level if no other status messages of C0183
are active