Troubleshooting and fault elimination, System error messages general error messages – Lenze EVS9332xK User Manual
Page 402
Troubleshooting and fault elimination
System error messages
General error messages
9.3
9.3.1
l
9.3−2
EDSVS9332K EN 8.0−07/2013
Remedy
Cause
Description
Fault message
Remedy
Cause
Description
Display
No.
x053
OH3
Motor temperature
> +150
C threshold
(temperature detection via
resolver or incremental value
encoder)
Motor is thermally overloaded
due to:
l
Impermissible continuous
current
l
Frequent or too long
acceleration processes
l
Check drive dimensioning.
l
Switch off monitoring
(C0583 = 3).
No PTC/temperature contact
connected.
Correct wiring.
x054
OH4
Heatsink temperature > C0122
Ambient temperature T
u
> +40
C
or > +50
C
l
Allow module to cool and
ensure better ventilation.
l
Check ambient temperature in
the control cabinet.
l
Switch off monitoring
(C0582 = 3).
Heatsink is very dirty.
Clean heatsink
Wrong mounting position
Change mounting position.
The value specified under C0122
is set too low.
Enter a higher value under C0122.
x057
OH7
Motor temperature > C0121
(temperature detection via
resolver or incremental value
encoder)
Motor is thermally overloaded
due to:
l
Impermissible continuous
current
l
Frequent or too long
acceleration processes
l
Check drive dimensioning.
l
Switch off monitoring
(C0584 = 3).
No PTC/temperature contact
connected.
Correct wiring.
The value specified under C0121
is set too low.
Enter a higher value in C0121.
x058
OH8
Motor temperature via inputs T1
and T2 is too high.
Motor is thermally overloaded
due to:
l
Impermissible continuous
current
l
Frequent or too long
acceleration processes
l
Check drive dimensioning.
l
Switch off monitoring
(C0585 = 3).
Terminals T1 and T2 are not
connected
Connect PTC/temperature
contact.
x061
CE0
Automation interface (AIF)
communication error
Faulty transfer of control
commands via AIF.
l
Plug in the communication
module/keypad XT firmly,
screw down, if necessary.
l
Switch off monitoring
(C0126 = 3).
x062
CE1
Communication error on the
process data input object
CAN1_IN
CAN1_IN object receives faulty
data or communication is
interrupted.
l
Check wiring at X4.
l
Check sender.
l
Increase monitoring time
under C0357/1, if necessary.
l
Switch off monitoring
(C0591 = 3).
x063
CE2
Communication error on the
process data input object
CAN2_IN
CAN2_IN object receives faulty
data or communication is
interrupted.
l
Check wiring at X4.
l
Check sender.
l
Increase monitoring time
under C0357/2, if necessary.
l
Switch off monitoring
(C0592 = 3).
x064
CE3
Communication error on the
process data input object
CAN3_IN
CAN3_IN object receives faulty
data or communication is
interrupted.
l
Check wiring at X4.
l
Check sender.
l
Increase monitoring time
under C0357/3, if necessary.
l
Switch off monitoring
(C0593 = 3).