Configuration, Monitoring functions – Lenze EVS9332xK User Manual
Page 272
Configuration
Monitoring functions
8
8.3
l
8.32
EDSVS9332K
EN 8.0−07/2013
Possible fault responses
l Lenze setting
ü Can be set
Monitoring
Off
Fail−QSP
Warning
Message
TRIP
Code
Source
Description
Fault message
0015
OC5
Device utilisation I x t (fix 100%)
MCTRL
l
0016
OC6
I
2
x t overload
MCTRL
l
0018
OC8
I
2
x t overload advance warning
MCTRL
C0606
ü
l
ü
x032
LP1
Failure of a motor phase
(current limit adjustable under C0599)
Caution: Can only be used with asynchronous motors. The
function block MLP1 must be entered in C0465.
MCTRL
C0597
ь
ь
l
x082
Sd2
Resolver error at X7
Note: If monitoring is switched off or in the case of "Warning",
the machine can reach very high speeds in the case of fault,
which may result in the damage of the motor and the machine
that is driven!
MCTRL
C0586
l
ь
ь
x083
Sd3
Interruption of the digital frequency coupling. The input signal
˜Lamp Control˜ at X9/8 is LOW
Please note: In the case of "Warning" (C0587 = 2), the drive can
be destroyed if the fault is not eliminated in time!
MCTRL
C0587
l
ь
ь
x085
Sd5
At analog input X6/1, X6/2, the input current is < 2 mA
Monitoring only possible if C0034 = 1
MCTRL
C0598
ь
ь
l
x087
Sd7
Absolute value encoder error at X8
MCTRL
ü
l
x088
Sd8
SinCos encoder error at X8
(filter setting under C0575)
MCTRL
C0580
ü
l
Speed
x190
nErr
Speed control error
(speed window adjustable under C0576)
MCTRL
C0579
ь
ь
ь
l
x200
NMAX
Maximum speed (C0596) has been exceeded.
MCTRL
l
Time−out / overflow
0105
H05
Internal fault (memory)
Internal
l
x153
P03
Following error (digital frequency > C0255)
Internal
C0589
ü
l
ü
x163
P13
Angle controller overflow
Internal
C0590
l
ь
ь
x169
P19
Input signal at X9 is limited
Internal
C1292
ü
l
ü
Parameter setting
0072
PR1
Check sum error in parameter set 1
Internal
l
0074
PEr
Program error
Internal
l
0075
PR0
Error in the parameter sets
Internal
l
0079
PI
Error during parameter initialisation
Internal
l
x089
PL
Error during rotor position adjustment
Internal
l
Explanation of the error numbers: