Commissioning – Lenze EVS9332xK User Manual
Page 224
Commissioning
Transfer of motion profiles
Transfer of profile data from the PLC/IPC to the controller
6.11
6.11.4
l
6.11−8
EDSVS9332K EN 8.0−07/2013
Checking the X axis
9300kur033
Fig. 6.11−6
Checking the X axis of the profile
)
Note!
The data for the X axis must be entered in ascending order.
Otherwise the drive may operate incorrectly (e.g. CCR trip) or
execute uncontrolled movements.
The entry of data in X direction is checked with code
C0501/1 = 0:
ƒ
Correct entry: The controller responds with the "ACK"
message.
ƒ
Faulty entry: The controller responds with the
"INV_VALUE_RANGE" message (error number 13). Code
C0501/1 contains the faulty interpolation point. Further error
messages can be found in chapter "Troubleshooting and fault
elimination".
Excerpt from the attribute table
Code
Index
DS
DA
DT
Format
DL
LCM−R
/W
Condition
dec
hex
C0387
24188
5E7C
E
1
FIX32
VD
4
Ra/Wa
C0389
24186
5E7A
E
1
FIX32
VD
4
Ra/Wa
C0390
24185
5E79
A
1
I32
VH
4
Ra/Wa
C0501
24074
5E0A
A
1
FIX32
VD
4
Ra/Wa
C0502
24073
5E09
A
1
I32
VH
4
Ra/W
C0504
24071
5E07
A
6
U32
VH
4
Ra/W
C0505
24070
5E06
A
4
U32
VH
4
Ra/W
C0511
24064
5E00
A
2
FIX32
VD
4
Ra/W
C0512
24063
5DFF
A
2
FIX32
VD
4
Ra/W
C1317
23258 5ADA
E
1
FIX32
VD
4
Ra/Wa CINH