Configuration – Lenze EVS9332xK User Manual
Page 322

Configuration
Code table
8.4
l
8.4−48
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C1072
s
® Selection list 3 RFGPH2, RFGPH3
Configuration of input signals
1 CFG:
RFGPH2−SET
1000 FIXED0INC
2 CFG:
RFGPH2−ACT
1000 FIXED0INC
3 CFG:
RFGPH3−SET
1000 FIXED0INC
4 CFG:
RFGPH3−ACT
1000 FIXED0INC
C1073
g
RFGPH2, RFGPH3
Display of input signals
1 (C1072/1)
... ...
4 (C1072/4)
C1074
0
1
2
RFGPHx−PHOUT = 0
RFGPHx−PHOUT = ACT
RFGPHx−PHOUT = SET
RFGPH2, RFGPH3
Mode for reset
1
0
RFGPH2−PHOUT
2
0
RFGPH3−PHOUT
C1075
RFGPH2
Mode
0
Without limit stop
The output signal at RFGPH2−PHOUT
continuously follows the setpoint at
RFGPH2−SET
1
With limit stop
The output signal at RFGPH2−PHOUT follows
the setpoint at RFGPH2−SET for the length of
a positioning process.
After a HIGH−LOW edge at RFGPH2−STOP, the
output signal continues to follow the
setpoint again.
C1076
RFGPH3
Mode
0
Without limit stop
The output signal at RFGPH3−PHOUT
continuously follows the setpoint at
RFGPH3−SET
1
With limit stop
The output signal at RFGPH3−PHOUT follows
the setpoint at RFGPH3−SET for the length of
a positioning process.
After a HIGH−LOW edge at RFGPH3−STOP, the
output signal continues to follow the
setpoint again.
C1077
0
{1 inc}
32767 RFGPH2, RFGPH3
1
5
RFGPH2: Catch
2
5
RFGPH3: Catch
C1078
0
{0.0001
rpm}
14000.0000 RFGPH2, RFGPH3
1
200.0
000
RFGPH2: N
max.
forward
2
200.0
000
RFGPH2: N
max.
return
3
200.0
000
RFGPH3: N
max.
forward
4
200.0
000
RFGPH3: N
max.
return