Technical data, Rated data operation at 480 v – Lenze EVS9332xK User Manual
Page 45
Technical data
Rated data
Operation at 480 V
3.3
3.3.2
l
3.3−3
EDSVS9332K EN 8.0−07/2013
9300
Mains current
1)
Typical motor power
Output power
Power loss
With
mains choke
Without
mains choke
ASM
(4−pole)
8 kHz
2)
U, V, W
+U
G
, −U
G
3)
Type
I
r
[A]
I
r
[A]
P
r
[kW]
P
r
[hp]
S
r8
[kVA]
P
DC
[kW]
P
V
[W]
EVS9321−xK
1.5
2.1
0.37
0.5
1.2
2.0
100
EVS9322−xK
2.5
3.5
0.75
1.0
2.1
0.75
110
EVS9323−xK
3.9
5.5
1.5
2.0
3.2
2.2
140
EVS9324−xK
7.0
˘
3.0
4.0
5.8
0.75
200
EVS9325−xK
12.0
16.8
5.5
7.5
10.8
0
260
EVS9326−xK
20.5
˘
11.0
15.0
18.5
0
390
EVS9327−xK
27.0
43.5
18.5
25.0
25.0
12
430
EVS9328−xK
44.0
˘
30.0
40.0
37.0
4.8
640
EVS9329−xK
53.0
˘
37.0
50.0
46.6
0
810
EVS9330−xK
78.0
˘
45.0
60.0
69.8
6
1100
EVS9331−xK
100
˘
55.0
75.0
87.3
0
1470
EVS9332−xK
135
˘
90.0
125
104
6
1960
Bold print = Lenze setting
1)
Mains currents at 8 kHz switching frequency
2)
Switching frequency of the inverter
3)
Power which can additionally be drawn from the DC bus at operation with power−adapted motor
9300
Output currents
8 kHz
1)
16 kHz
1)
Rated current
Maximum
current
2)
Standstill current
Rated current
Maximum
current
2)
Standstill current
Type
I
r8
[A]
I
M8
[A]
I
08
[A]
I
r16
[A]
I
M16
[A]
I
016
[A]
EVS9321−xK
1.5
2.25
2.3
1.1
1.65
1.7
EVS9322−xK
2.5
3.75
3.8
1.8
2.7
2.7
EVS9323−xK
3.9
5.85
5.9
2.9
4.35
4.4
EVS9324−xK
7.0
10.5
10.5
5.2
7.8
7.8
EVS9325−xK
13.0
19.5
19.5
9.7
14.6
14.6
EVS9326−xK
22.3
33.5
22.3
14.5
21.8
14.5
EVS9327−xK
30.4
45.6
30.4
19.2
28.8
19.2
EVS9328−xK
44.7
67.1
44.7
28.2
42.3
28.2
EVS9329−xK
56.0
84.0
49.0
35.0
52.5
25.0
EVS9330−xK
84.0
126
72.0
55.0
82.5
36.0
EVS9331−xK
105
157.5
105
65.0
97.5
58.0
EVS9332−xK
125
187.5
111
80.0
120
58.0
Bold print = Lenze setting
1)
Switching frequency of the inverter
2)
The currents apply to a periodic load change cycle with max. 1 minute overcurrent duration and 2
minutes base load duration at max. 75 % I
r