Configuration – Lenze EVS9332xK User Manual
Page 345

Configuration
Code table
8.4
l
8.4−71
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C1444
s
® Selection list 3 WELD1
Configuration of input signals
1 WELD1−XIN
1000 FIXED0INC
Input X position
2 WELD1−LEN−O
1000 FIXED0INC
Length of the closing phase
3 WELD1−LEN−C
1000 FIXED0INC
Length of the opening phase
4 WELD1−LEN
1000 FIXED0INC
Length of the profile
5 WELD1−TIME
1000 FIXED0INC
Welding time in ms (1 inc. = 1 ms)
C1445
g
{1 inc.}
WELD1
Display of input signals
1 (C1444/1)
... ...
5 (C1444/5)
C1446
0
WELD1
0
Weld1 mode: Time
The value at input Weld−Time" is interpreted
as time.
1
Weld1 mode: Distance
The value at input Weld−Time" is interpreted
as distance.
2
Weld1 mode: Distance with saving
The value at input Weld−Time" is interpreted
as distance. WELD−TIME" is saved for the
further cycle when phase 2 of the profile is
started.
C1448
s
CFG:
WELD1−BREAK
1000 FIXED0
® Selection list 2 WELD1
Configuration of digital input signal
C1449 (C1448)
g
WELD1
Display of digital input signal
C1450
s
® Selection list 3 CONVPHPHD1, CONVPHPHD2
Configuration of input signals
1 CONVPHPHD1−
IN
1000 FIXED0INC
2 CONVPHPHD2−
IN
1000 FIXED0INC
C1451
g
{1 inc.}
CONVPHPHD1, CONVPHPHD2
Display of input signals
1 (C1450/1)
2 (C1450/2)
C1452
1
−32767
{1}
32767 CONVPHPHD1
Numerator
C1453
1
1
{1}
32767 CONVPHPHD1
Denominator
C1454
s
CONVPHPHD2−
RESET
1000 FIXED0
® Selection list 2 CONVPHPHD2
Configuration of digital input signal
C1455 (C1454)
g
CONVPHPHD2
Display of digital input signal
C1456
s
CONV7−DFIN
1000 FIXEDPHI−0
® Selection list 4 CONV7
Configuration of input signals
C1457 (C1456)
g
CONV7
Display of input signals
C1458
1
−32767
{1}
32767 CONV7
Numerator
C1459
1
1
{1}
32767 CONV7
Denominator
C1460
0
0
1
Analog setpoint
Digital frequency setpoint
VMAS1
Setpoint source selection