Configuration – Lenze EVS9332xK User Manual
Page 304
Configuration
Code table
8.4
l
8.4−30
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0693
s
® Selection list 1 CMP3
Configuration of analog input signals
1 CMP3−IN1
1000 FIXED0%
2 CMP3−IN2
1000 FIXED0%
C0694
g −199.99
{0.01 %}
199.99 CMP3
Display of analog input signals
1 (C0693/1)
2 (C0693/2)
C0695 FUNCTION
2
1
2
IN 1 < IN2
|IN1| < |IN2|
PHCMP1
Selection of the function for comparing
inputs IN1 and IN2
C0697
s
® Selection list 3 PHCMP1
Configuration of input signals
1 IN
1000 FIXED0INC
2 IN
1000 FIXED0INC
C0698
g −2147483647
{1}
2147483647 PHCMP1
Display of input signals
1 (C0697/1)
2 (C0697/2)
C0700
s
IN
19523 FCODE−472/3
® Selection list 1 ANEG1
Configuration of analog input signal
C0701 (C0700)
g −199.99
{0.01 %}
199.99
C0703
s
IN
1000 FIXED0%
® Selection list 1 ANEG2
Configuration of analog input signal
C0704 (C0703)
g −199.99
{0.01 %}
199.99
C0710 FUNCTION
0
0
1
2
Rising edge
Falling edge
Both edges
TRANS1
Edge evaluation
With the corresponding signal edge at IN,
OUT switches to HIGH
C0711 PULSE T
0.001 0.001
{0.001 s}
60.000 TRANS1
Pulse duration of TRANS1
C0713
s
IN
1000 FIXED0
® Selection list 2 TRANS1−IN
Configuration of digital input signal
C0714 (C0713)
g
TRANS1−IN
Display of digital input signal
C0715 FUNCTION
0
0
1
2
Rising edge
Falling edge
Both edges
TRANS2
Edge evaluation
With the corresponding signal edge at IN,
OUT switches to HIGH
C0716 PULSE T
0.001 0.001
{0.001 s}
60.000 TRANS2
Pulse duration
C0718
s
IN
1000 FIXED0
® Selection list 2 TRANS2
Configuration of digital input signal
C0719 (C0718)
g
TRANS2
Display of digital input signal
C0720 FUNCTION
2
0
1
2
On delay
Off delay
On/off delay
DIGDEL1
Function selection
C0721 DELAY T
1.000 0.001
{0.001 s}
60.000 DIGDEL1
Setting of the delay time
C0723
s
IN
1000 FIXED0
® Selection list 2 DIGDEL1
Configuration of digital input signal
C0724 (C0723)
g
DIGDEL1
Display of digital input signal