Configuration
Code table
8.4
l
8.4−20
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0464 CUSTOMER I/F
g 0
1
Original
Changed
Customer interface
Status of selected basic configuration
l
Reassignment of terminals in a basic
configuration of C0005 does not change
C0005 and sets C0464 = 1
l
Adding or removing function blocks or
changing the signal flow between the
function blocks in a basic configuration of
C0005 sets C0005 = 0 and C0464= 1
C0465
s
FB LIST
®
® Selection list 5 FB processing table
Contains the program for signal processing
(sequence in which the function blocks are
processed)
à
Depending on C0005. Changing C0005
loads the assigned processing table
à
Valid for C0005 = 1000
l
After changing the signal flow, the
processing table must be adapted.
Otherwise the controller may use the
wrong signals!
l
The function blocks DIGIN, DIGOUT,
AIF−IN, CAN−IN and MCTRL are always
processed and do not have to be entered
in the table.
1
200
2
0
3
50
4
0
5
0
6
55
7
0
8
0
9
10250
10
0
11
0
12
0
13
5650
14
0
15
0
16
5050
...
0
19
5700
...
0
22
10650
...
0
25
70
..
0
28
75
...
0
31
250
...
0
41
25000
42
20000
...
0
49
0
50
0
C0466 CPU T REMAIN
g
Remaining process time
Time remaining for processing function
blocks
C0469
s
FUNKTION KEY
STOP
2
0
1
2
Switched off
Set controller inhibit
Set quick stop
Setting the function of the keypad STOP key