Open and closed loop control, Technical data – Lenze EVS9332xK User Manual
Page 41
Technical data
Open and closed loop control
3.2
l
3.2−1
EDSVS9332K EN 8.0−07/2013
3.2
Open and closed loop control
Open and closed loopcontrol
Switching frequency
8 kHz or 16 kHz
Digital setpoint
selection
Accuracy
± 0.005 Hz (= ± 100 ppm)
Analog setpoint
selection
Linearity
± 0.15 %
Signal level: 5 V or 10 V
Temperature
sensitivity
± 0.1 %
0 ... 50 °C
Offset
± 0.1 %
Analog inputs
Analog outputs
l
2 inputs (bipolar)
l
2 outputs (bipolar)
Digital inputs
Digital outputs
l
5 inputs (freely assignable)
l
1 input for controller inhibit
l
4 outputs (freely assignable)
l
1 resolver input; design: 9−pole Sub−D socket
l
1 incremental encoder input (500 kHz, TTL level); design: 9−pole Sub−D socket (pin)
l
1 digital frequency input (500 kHz, TTL level); design: 9−pole Sub−D socket (pin); can be optionally
used as incremental encoder input (500 kHz, TTL level)
l
1 digital frequency output (500 kHz, TTL level); design: 9−pole Sub−D socket
Cycle times
Digital inputs
1 ms
Digital outputs
1 ms
Analog inputs
1 ms
Analog outputs
1 ms (smoothing time:
t= 2 ms)