Commissioning – Lenze EVS9332xK User Manual
Page 226
Commissioning
Transfer of motion profiles
Transfer of profile data from the controller to the PLC/IPC
6.11
6.11.5
l
6.11−10
EDSVS9332K EN 8.0−07/2013
Profile data set (example)
Line
Data
Meaning
1
100
Version identifier
2
4293787648
Profile data
3
4293853166
Profile data
...
...
Profile data
1234
4294641604
Profile data
...
...
Profile data
1242
0
Profile data
1243
55932
Checksum
)
Note!
ƒ
C0505 can only be transferred by a control (PLC or Lenze Drive
PLC). C0505 cannot be addressed via GDC.
ƒ
Every line must be read.
ƒ
Each line may only be read once because the pointer in the
controller automatically jumps to the next element of the
profile data table after a transfer.
ƒ
Repeat the entire transmission process if an error occurs
during the transmission.
Extract from the table of attributes
Code
Index
DS
DA
DT
Format
DL
LCM−
R/W
Condition
dec
hex
C0387
24188 5E7Ch
E
1
FIX32
VD
4
RA/W special
C0504/x
24071 5E07h
A
2
U32
VH
4
RA/W special
C0505/x
24070 5E06h
A
2
B32
VH
4
RA/W special
C0506/x
24069 5E05h
A
2
FIX32
VD
4
RA
C0509
24066 5E02h
E
1
B32
VH
4
RA/W