Configuration, Code table – Lenze EVS9332xK User Manual
Page 306
Configuration
Code table
8.4
l
8.4−32
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0739 KANALANZAHL
4
1
{1}
4 OSZ
Number of channels to be measured
C0740 DATA READ
0
OSZ
1
0
0
{1}
65535 Selection of the starting point for reading out
the data memory. Allows selective access to a
memory block
2
0
0
1
Data reading inhibited
Data reading enabled
Inhibit "Read memory"
C0741
OSZ
1 VERSION OSZ
g
Version
2 LENGTH
MEMORY
Memory size
3 DATA WIDTH
Data width
4 NO. CHANNELS
Number of channels
C0742 LENGTH OF DB
g
OSZ
Display of data block length
C0743 READ DB
g
OSZ
Reading of an 8−byte data block
C0744 MEM: DEPTH
2048 0
1
2
3
4
5
6
512 measured values
1024 measured values
1536 measured values
2048 measured values
3072 measured values
4096 measured values
8192 measured values
OSZ
Adaptation of the memory size to the
measurement task
C0749
g
OSZ
Information on measured value storage
1 BRK:OFF INDEX
2 TRIGGER INDEX
3 END INDEX
C0750 VP DENOM
16
1
2
4
8
16
34
64
128
256
512
1024
2048
4096
8192
16384
Vp = 1
Vp = 1/2
Vp = 1/4
Vp = 1/8
Vp = 1/16
Vp = 1/32
Vp = 1/64
Vp = 1/128
Vp = 1/256
Vp = 1/512
Vp = 1/1024
Vp = 1/2048
Vp = 1/4096
Vp = 1/8192
Vp = 1/16384
DFRFG1
Denominator of the position controller gain
C0751 DFRFG1 TIR
1.000 0.001
{0.001 s}
999.900 DFRFG1
T
ir
(acceleration time)
C0752 MAX SPEED
3000 1
{1 rpm}
16000 DFRFG1
Maximum speed (here: maximum catch−up
speed)
C0753 DFRFG1 QSP
0.000 0.000
{0.001 s}
999.900 DFRFG1
Deceleration time T
if
when deceleration ramp
is activated
C0754 PH ERROR
2
.
10
9
10
{1 inc}
2
.
10
9
DFRFG1
Following error
C0755 SYN WINDOW
100
0
{1 inc}
65535 DFRFG1
Synchronisation window