Commissioning
Changing the assignment of the control terminals X5 and X6
Free configuration of analog outputs
6.9
6.9.4
l
6.9−4
EDSVS9332K EN 8.0−07/2013
6.9.4
Free configuration of analog outputs
ƒ The analog outputs (X6/62, X6/63) can be freely linked with internal
analog process or monitoring signals. The controller outputs a voltage
proportional to the internal signal at the analog outputs.
ƒ One signal source can be linked with several targets.
Analog outputs can be linked with internal analog signals by entering the
selection figure of the internal signal into the code of C0431 (AOUT1, X6/62)
or C0436 (AOUT2, X6/63).
Example
ƒ C0436 = 5006
ð signal source for X6/63 is the actual motor voltage
I
Tip!
ƒ
A list with all selection figures is included in the chapter
"Configuration"
® "Selection lists".
ƒ
For signal linkage we recommend the function block editor in
GDC (ESP−GDC2).
Set gain (C0108) and offset (C0109) to adapt the output signal to the
application.
With an internal signal of 100 % and a gain of 1, a voltage of 10 V is output
at the terminal.
Description
Linking signals
Adjustment