Technical data, Wiring of the standard device, Control terminals technical data – Lenze EVS9332xK User Manual
Page 150: 7 technical data
Wiring of the standard device
Control terminals
Technical data
5.8
5.8.7
l
5.8−10
EDSVS9332K EN 8.0−07/2013
5.8.7
Technical data
Safety relay K
SR
Terminal
Description
Field
Values
X11/K32
X11/K31
X11/33
X11/34
Safety relay K
SR
1st disconnecting path
Coil voltage at +20 °C
DC 24 V (20 ... 30 V)
Coil resistance at +20 °C
823
W ±10 %
Rated coil power
Approx. 700 mW
Max. switching voltage
AC 250 V, DC 250 V (0.45 A)
Max. AC switching capacity
1500 VA
Max. switching current (ohmic load)
AC 6 A (250 V), DC 6 A (50 V)
Recommended minimum load
> 50 mW
Max. switching rate
6 switchings per minute
Mechanical service life
10
7
switching cycles
Electrical service life
at 250 V AC
(ohmic load)
10
5
switching cycles at 6 A
10
6
switching cycles at 1 A
10
7
switching cycles at 0.25 A
at 24 V DC
(ohmic load)
6 × 10
3
switching cycles at 6 A
10
6
switching cycles at 3 A
1.5 × 10
6
switching cycles at 1 A
10
7
switching cycles at 0.1 A
Digital inputs, digital outputs
Terminal
Description
Field
Values
X5/28
Controller inhibit
(DCTRL−CINH)
2nd disconnecting path
PLC level, HTL
LOW: 0 ... +3 V
HIGH: +12 ... +30 V
X5/E1
X5/E2
X5/E3
X5/E4
X5/E5
Digital inputs
PLC level, HTL
LOW: 0 ... +3 V
HIGH: +12 ... +30 V
Input current per input
8 mA for +24 V
Cycle time
1 ms
X5/A1
X5/A2
X5/A3
X5/A4
Digital outputs
PLC level, HTL
LOW: 0 ... +3 V
HIGH: +12 ... +30 V
Load capacity per output
Maximally 50 mA
Load resistance
For +24 V at least 480
W
Cycle time
1 ms
X5/39
GND2
Reference potential for digital signals
Isolated to X6/7 (GND1)
X5/59
Connection of external
voltage source for backup
operation of the drive
controller in the case of
mains failure
Input voltage
DC 24 V (+18 ... +30 V)
Current consumption
Maximally 1 A for 24 V
X5/ST1
X5/ST2
STATE−BUS
Maximum number of nodes
20
Maximum length of the bus cable
5 m