Configuration – Lenze EVS9332xK User Manual
Page 298
Configuration
Code table
8.4
l
8.4−24
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0532 0−PULSE/TP
1
1
2
3
0−pulse
Touch probe
0−pulse and touch probe
DFSET zero pulse/touch probe
Selecting zero pulse, touch probe or zero
pulse and touch probe
C0533 VP DENOM
1
1
{1}
32767 DFSET Vp denominator
Gain factor denominator
C0534 0 PULSE FCT
0
0
1
2
10
11
12
13
Inactive
Continuous
Cont. switchable
Once, fast way
Once, CW
Once, CCW
Once, 2 × zero pulse
DFSET
Zero pulse function
C0535 SET 0 DIV
1
1
{1}
16384 DFSET
Setpoint zero pulse divider
C0536
g −32767
{1}
32767 DFSET
Display of analog input signals
1 (C0521)
2 (C0522)
3 (C0523)
C0537 (C0524)
g −199.99
{0.01 %}
199.99 DFSET
Display of analog input signal
C0538
g
DFSET
Display of digital input signals
1 (C0525)
2 (C0526)
3 (C0527)
C0539 (C0520)
g −32767
{1 rpm}
32767 DFSET
Display of input signal
C0540 FUNCTION
2
0
1
2
3
4
5
Analog input
Phase difference input
Resolver simulation + zero pulse
Resolver simulation, no zero pulse
X10 = X9
X10 = X8
DFOUT
Function of the encoder output
C0541
s
AN−IN
5001 MCTRL−NACT
® Selection list 1 DFOUT
Configuration of analog input
C0542
s
DF−IN
1000 FIXEDPHI−0
® Selection list 4 DFOUT
Configuration of digital frequency input
C0544
s
SYN−RDY
1000 FIXED0
® Selection list 2 DFOUT
Synchronisation signal for zero pulse
C0545 PH OFFSET
0
0
{1 inc}
65535 DFOUT
Phase offset
C0546 PULSE MIN SET
1000 1
{1inc}
2147483647 DFOUT
Masking (suppression) of interference pulses
at X5/E5 (setpoint pulse of the touch probe
signal)
l
The size of the masking window between
two setpoint pulses is set
C0547 (C0541)
g −199.99
{0.01 %}
199.99 DFOUT
Display of analog input signal
C0548 (C0544)
g 0
1 DFOUT
Display of digital input signal
C0549 (C0542)
g −32767
{1 rpm}
32767 DFOUT
Display of input signal