Configuration, Code table – Lenze EVS9332xK User Manual
Page 307
Configuration
Code table
8.4
l
8.4−33
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0756 OFFSET
0
−1
.
10
9
{1 inc}
1
.
10
9
DFRFG1
Offset
C0757 FUNCTION
0
0
1
TP start inactive
TP start active
DFRFG1
Function
C0758
s
IN
1000 FIXEDPHI−0
® Selection list 4 DFRFG1
Configuration of input signal
C0759
s
QSP
1000 FIXED0
® Selection list 2 DFRFG1
Configuration of digital input signal
C0760
s
STOP
1000 FIXED0
® Selection list 2 DFRFG1−STOP
Configuration of digital input signal
"Ramp function generator stop"
C0761
s
RESET
1000 FIXED0
® Selection list 2 DFRFG1
Configuration of digital input signal
Reset of integrators
C0764
g
DFRFG1
Display of digital input signals
1 (C0759)
2 (C0760)
3 (C0761)
C0765 (C0758)
g −32767
{1 rpm}
32767 DFRFG1
Display of input signal
C0766 SPEED DIR
1
1
2
3
both directions (CW/CCW)
positive direction only (CW)
negative direction only (CCW)
DFRFG1
Selection of the direction of rotation
C0768
s
SET
1000 FIXEDPHI−0
® Selection list 4 DFRFG1
Configuration of input signal
Start speed
C0769 (C0768)
g
DFRFG1
Display of input signal
C0770
s
D
1000 FIXED0
® Selection list 2 FLIP1
Data input
Configuration of digital input signal
C0771
s
CLK
1000 FIXED0
® Selection list 2 FLIP1
Configuration of clock input signal
C0772
s
CLR
1000 FIXED0
® Selection list 2 FLIP1
Configuration of reset input signal
C0773
g
FLIP1
Display of digital input signals
1 (C0770)
2 (C0771)
3 (C0772)
C0775
s
D
1000 FIXED0
® Selection list 2 FLIP2
Data input
Configuration of digital input signal
C0776
s
CLK
1000 FIXED0
® Selection list 2 FLIP2
Configuration of clock input signal
c0777
s
CLR
1000 FIXED0
® Selection list 2 FLIP2
Configuration of reset input signal
C0778
g
FLIP1
Display of digital input signals
1 (C0775)
2 (C0776)
3 (C0777)
C0780
s
N
50
AIN1−OUT
® Selection list 1 NSET
Configuration of input signal for main
setpoint