Configuration – Lenze EVS9332xK User Manual
Page 327

Configuration
Code table
8.4
l
8.4−53
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C1176
g
AND6
Display of digital input signals
1 (C1175/1)
2 (C1175/2)
3 (C1175/3)
C1178
s
® Selection list 2 AND7, AND8, AND9
Configuration of digital input signals
1 IN
1000 FIXED0
AND7−IN1
2 IN
1000 FIXED0
AND7−IN2
3 IN
1000 FIXED0
AND7−IN3
4 IN
1000 FIXED0
AND8−IN1
5 IN
1000 FIXED0
AND8−IN2
6 IN
1000 FIXED0
AND8−IN3
7 IN
1000 FIXED0
AND8−IN4
8 IN
1000 FIXED0
AND8−IN5 (NOT)
9 IN
1000 FIXED0
AND9−IN1
10 IN
1000 FIXED0
AND9−IN2
11 IN
1000 FIXED0
AND9−IN3
12 IN
1000 FIXED0
AND9−IN4
13 IN
1000 FIXED0
AND9−IN5 (NOT)
C1179
g
AND7, AND8, AND9
Display of digital input signals
1 (C1178/1)
... ...
13 (C1178/13)
C1180
s
® Selection list 2 PHINT4, PHINT5
Configuration of digital input signals
1 LOAD
1000 FIXED0
PHINT4−LOAD
2 RESET
1000 FIXED0
PHINT4−RESET
3 RESET
1000 FIXED0
PHINT5−RESET
4 LOAD
1000 FIXED0
PHINT5−LOAD
5 TP−ENABLE
1000 FIXED0
PHINT5−TP−ENABLE
6 TP−EDGE−SELEC
T
1000 FIXED0
PHINT5−TP−EDGE−SELECT
C1181
g
PHINT4, PHINT5
Display of digital input signals
1 (C1180/1)
... ...
6 (C1180/6)
C1182
s
® Selection list 3 PHINT4, PHINT5
Configuration of phase input signals
1 H−VALUE
1000 FIXED0INC
PHINT4−H−VALUE
2 L−VALUE
1000 FIXED0INC
PHINT4−L−VALUE
3 SET
1000 FIXED0INC
PHINT4−SET
4 SET
1000 FIXED0INC
PHINT5−SET
5 H−VALUE
1000 FIXED0INC
PHINT5−H−VALUE
6 TP−POS
1000 FIXED0INC
PHINT5−TP−POS
7 X−OFFSET
1000 FIXED0INC
PHINT5−X−OFFSET