Installing of the standard device – Lenze EVS9332xK User Manual
Page 57

Installing of the standard device
Standard devices in the power range 0.37 ... 11 kW
Mounting in "cold plate" technique
4.1
4.1.4
l
4.1−5
EDSVS9332K EN 8.0−07/2013
a
c1
c
c
a
a
c
g
g
g
b1
b1
b1
d
d
d
b
b
b
L
L
L
2
1
0
e
< 75 °C
3
9300std064
Fig. 4.1−3
Dimensions for mounting in "cold plate" technique 0.37 ... 11 kW
9300
Dimensions [mm]
Type
a
b
b1
c
c1
d
e
1)
g
EVS9321−CK
EVS9322−CK
0
78
381
350
48
˘
367
168
6.5
EVS9323−CK
EVS9324−CK
1
97
381
350
67
˘
367
168
6.5
EVS9325−CK
EVS9326−CK
2
135
381
350
105
38
367
168
6.5
1)
For a fieldbus module plugged onto X1, consider mounting space for connecting cables
Apply heat conducting paste before screwing together the cooler and
cooling plate of the drive controller so that the heat transfer resistance is as
low as possible.
1. Fasten the fixing bracket with sheet metal screws 3.5 × 13 mm at the
top and bottom of the drive controller
3.
2. Clean the contact surface of cooler and cooling plate with spirit.
3. Apply a thin coat of heat conducting paste with a filling knife or brush.
– The heat conducting paste in the accessory kit is sufficient for an area
of approx. 1000 cm
2
.
4. Mount the drive controller on the cooler.
Dimensions
Mounting