Configuration, Code table – Lenze EVS9332xK User Manual
Page 288
Configuration
Code table
8.4
l
8.4−14
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0263 MPOT1 TIF
10.0
0.1
{0.1 s}
6000.0 MPOT1
Deceleration time
(referring to change 0 ... 100 %)
C0264 MPOT1
ON/OFF
0
0
1
2
3
4
5
No change
Deceleration with T
if
to 0%
Deceleration with T
if
to C0261
Jump with T
if
= 0 to 0%
Jump with T
if
= 0 to C0261
Acceleration with T
ir
to C0260
MPOT1
Functions which can be executed when the
motor potentiometer is deactivated via input
MPOT1−INACTIVE.
C0265 MPOT1 INIT
0
0
1
2
Value during mains failure
Lower limit of C0261
0 %
MPOT1
Initialisation
Value which is accepted at mains switching
and activated motor potentiometer
C0267
s
® Selection list 2 MPOT1
Configuration of digital input signals
1 UP
1000 FIXED0
2 DOWN
1000 FIXED0
C0268
s
MPOT1−INACT
1000 FIXED0
® Selection list 2 MPOT1
Configuration of digital input signal
C0269
g
1 (C0267/1)
2 (C0267/2)
3 (C0268)
C0291 SSC OVERRIDE
0
0
{1 rpm}
16000 SSC override frequency
Override frequency for the transition from
sensorless control to controlled operation
C0292 SSC IM SET
0.00
0.00
{0.01 A}
500.00 SSC Im setpoint
Motor current setpoint.
For sensorless control, set 1.0 to 1.1−fold
increased rated motor current.
C0293 SSC DYNAMIC
0.00
0.00
{0.01 %}
199.00 SSC dynamic constant
C0294 VP FRQ CTRL
®
0.0
{0.1}
99.9 Vp frequency controller
Proportional gain of frequency controller
à
Depending on C0086
C0295 TN FRQ CTRL
®
2
{1 ms}
20000 Tn frequency controller
Reset time of frequency controller
à
Depending on C0086
C0296 DYNAMIC
CONST
100
0
{0.1}
32767 Dynamic constant
C0325 VP2 ADAPT
1.0
0.1
{0.1}
500.0 PCTRL1 Adaptation Vp2
Process controller adaptation gain (V
p2
)
C0326 VP3 ADAPT
1.0
0.1
{0.1}
500.0 PCTRL1 Adaptation Vp3
Process controller adaptation gain (V
p3
)
C0327 SET2 ADAPT
100.0
0
0.00
{0.01 %}
100.00 PCTRL1 Adaptation nset2
Speed setpoint threshold of process
controller adaptation (condition: C0327 >
C0328)
C0328 SET1 ADAPT
0.00
0.00
{0.01 %}
100.00 PCTRL1 Adaptation nset1
Speed setpoint threshold of process
controller adaptation (condition: C0328 <
C0327)