Installing of the standard device – Lenze EVS9332xK User Manual
Page 63
Installing of the standard device
Standard devices in the power range 15 ... 30 kW
Mounting in "cold plate" technique
4.2
4.2.4
l
4.2−5
EDSVS9332K EN 8.0−07/2013
d
b1
c
c1
a
a1
g
e
< 75 °C
L
b
9300std067
Fig. 4.2−3
Dimensions for mounting in "cold plate" technique 15 ... 22 kW
9300
Dimensions [mm]
Type
a
a1
b
b1
c
c1
d
e
1)
g
EVS9327−CK
EVS9328−CK
234
250
381
350
110
220
367
171
6.5
1)
For a fieldbus module plugged onto X1, consider mounting space for connecting cables
Apply heat conducting paste before screwing together the cooler and
cooling plate of the drive controller so that the heat transfer resistance is as
low as possible.
1. Clean the contact surface of cooler and cooling plate with spirit.
2. Apply a thin coat of heat conducting paste with a filling knife or brush.
– The heat conducting paste in the accessory kit is sufficient for an area
of approx. 1000 cm
2
.
3. Mount the drive controller on the cooler.
Dimensions
Mounting