Configuration – Lenze EVS9332xK User Manual
Page 313
Configuration
Code table
8.4
l
8.4−39
EDSVS9332K EN 8.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0853 TYPE OUT.W3
0
0
1
2
Analog signal
Digital 16−31
High phase
AIF−OUT
Configuration of process output word 3 for
the automation interface AIF (X1)
C0854 TYPE OUT.W1
0
0
3
Analog signal
D2: LOW phase
AIF−OUT
Configuration of process output word 1 for
the automation interface AIF (X1)
C0855 IN
g
AIF
Hexadecimal process input words for the
automation interface X1
1
Bit 00
{1}
Bit 15 AIF−IN
2
Bit 16
{1}
Bit 31 AIF−IN
C0856
g −199
{1 %}
199 AIF−IN
Decimal process input words
Display: 100.00 % = 16384
1 IN.W1
2 IN.W2
3 IN.W3
C0857 IN.D1
g −2147483648
{1}
2147483647 AIF−IN
32−bit phase information
C0858
g −199.99
{0.01 %}
199.99 AIF−OUT
Process output words
Display: 100 % = 16384
1 OUT.W1
2 OUT.W2
3 OUT.W3
C0859 OUT.D1
g −2147483648
{1}
2147483647 AIF−OUT
32−bit phase information
C0860
s
® Selection list 1 AIF
1 OUT1.W1
5001
2 OUT1.W2
1000 FIXED0%
3 OUT1.W3
1000 FIXED0%
4 OUT2.W1
1000 FIXED0%
5 OUT2.W2
1000 FIXED0%
6 OUT2.W3
1000 FIXED0%
7 OUT2.W4
1000 FIXED0%
8 OUT3.W1
1000 FIXED0%
9 OUT3.W2
1000 FIXED0%
10 OUT3.W3
1000 FIXED0%
11 OUT3.W4
1000 FIXED0%
C0861
s
® Selection list 3 AIF
1 OUT1.D1
1000 FIXED0INC
2 OUT2.D1
1000 FIXED0INC
3 OUT3.D1
1000 FIXED0INC
C0863
g 0
1 AIF
1 IN1 (0−15)
2 IN1 (16−31)
3 IN2 (0−15)
4 IN2 (16−31)
5 IN3 (0−15)
6 IN3 (16−31)