Current characteristics, Technical data, 5 hz| and heatsink temperatures j – Lenze EVS9332xK User Manual
Page 49
Technical data
Current characteristics
3.4
l
3.4−1
EDSVS9332K EN 8.0−07/2013
3.4
Current characteristics
The maximum output current of the EVS9326 ... EVS9332 devices is limited
under certain operating conditions:
ƒ At output frequencies f
out
< |5 Hz| and heatsink temperatures
J
K
> 40° C.
ƒ The current limitation depends on the switching frequency.
0
0
0
0
5
5
fout [Hz]
fout [Hz]
K
< 40 °C
K
= 80 °C
0
1
I
OUT
I
OUT
I
max
I
max
I
0max
I
0max
9300vec132
Fig. 3.4−1
Current derating characteristics
0 Operation at switching frequency f
chop
= 8 kHz (C0018 = 1)
The current limitation follows the characteristic curve
At output frequencies f
out
< |5 Hz| and heatsink temperatures
J
K
= 40 ... 80 °C, the current limit is steplessly adjusted in the
range
1 Operation at switching frequency f
chop
= 16 kHz (C0018 = 2)
The current limitation follows the characteristic curve and is independent of
the heatsink temperature
At automatic change−over of the switching frequency (C0018 = 0), the controller
operates at f
chop
= 16 kHz. The current limitation follows the characteristic
curve
1.
If an increased torque is required (e.g. acceleration processes), the controller
automatically switches over to f
chop
= 8 kHz. The current limitation follows the
characteristic curve
0.
9300
I
0max
[A]
1)
I
0max
[A]
2)
f
chop
= 8 kHz
f
chop
= 16 kHz
U
mains
U
mains
400 V
480 V
400 V
480 V
EVS9326−xK
23.5
22.3
15.3
14.5
EVS9327−xK
32.0
30.4
20.8
19.2
EVS9328−xK
47.0
44.7
30.6
28.2
EVS9329−xK
52.0
49.0
33.0
25.0
EVS9330−xK
80.0
72.0
45.0
36.0
EVS9331−xK
110
105
70.0
58.0
EVS9332−xK
126
111
72.0
58.0
1)
Maximum available output current at an output frequency f
out
= |0 Hz| and heatsink temperature
J
K
= 80 °C
2)
Maximum available output current at an output frequency f
out
= |0 Hz|