Direct Injection: Inlet Restriction

The injection pump has a vacuum switch that is used to warn operators of
any restriction at the inlet of the pump. The sensor is a normally closed
switch that opens if a restriction is encountered in the injection system. A
warning will be displayed for the operator if the vacuum switch opens due to
restriction. See table below for pin locations. The operator can test the
system by unplugging the sensor, which will trigger the warning. If the
operator jumps pins A and C, the warning will end.

VACUUM SWITCH PIN OUTS

T

ROUBLESHOOTING

D

IRECT

C

OMMAND

G

RANULAR

A

PPLICATIONS

Problem: Individual implement Sections shown in the Implement Icon on the Map Zoom Detail

Screen do not turn green.
Solution:

1. Make sure ground speed has registered a value greater than zero on the display.

2. Verify a target rate greater than zero is entered into the display.

Module Auxiliary Connection

12-Pin Socket

3-Pin Shroud

Power (12V)

11

A

Signal 9

B

Ground

8

C

Module Auxiliary Connection

12-Pin Socket

3-Pin WP Tower

Power (12V)

2

C

Signal 10

A