beautypg.com

Battery power pin-outs, Direct injection: pump runs full speed, Attery – Ag Leader EDGE Ver.4.5 Users Manual User Manual

Page 170: Ower

background image

158

B

ATTERY

P

OWER

P

IN

-O

UTS

Direct Injection: Pump Runs Full Speed

• Digital Pump Speed Sensor

The injection pump’s
digital pump speed
sensor is used to provide
actual rate feedback to
the display. If the display
is not receiving an actual
rate the pump will run full
speed and provide a
“Rate Not Responding”
warning message. See
Digital Pump Speed Pin
out table below for pin
locations. With the
section valves on the
cabling can be tested by
pulsing the signal and
ground pins to verify the
total applied increases, it

is always best to pulse the pins at least 10 times to make sure the total applied will increase by a
noticeable amount.

2 Pin Deutsch Plug

2 Pin Deutsch

Receptacle

2 Pin WP Tower

Power 12 V

1

1

A

Ground

2

2

B

Module Auxiliary Connection

12-Pin Socket

3-Pin Conxall

Power (5V)

12

2

Signal (5V)

3

3

Ground

6

1