beautypg.com

Control valve settings for self-propelled sprayers, Ontrol, Alve – Ag Leader EDGE Ver.4.5 Users Manual User Manual

Page 133: Ettings for, Ropelled, Prayers

background image

121

A

PPLICATION

C

ONTROL

V

ALVE

S

ETTINGS FOR

S

ELF

-P

ROPELLED

S

PRAYERS

Control Valve Settings for Self-Propelled Sprayers

Flow Control

Valve or

Sprayer Model

(and year if

applicable)

Control System

PWM

Frequen

cy

Typical

Gain

Range

Zero

Offset

Allowabl

e Error

Valve

Respon

se

1

Valve

Respon

se

2

Respon

se

Thresho

ld

Apache
510/710/
1010/1210
(2006 and up)

In-line Servo

2%

100%

24%

Use a
starting
value of
5.* See
note
below.

All Case IH
sprayers when
using AIM
Command

AIM Command
In-line servo

2%

100%

24%

3

Case IH
Surveyor with
A-post

Non-AIM
Command
Mode PWM
12-volt

122

**700-
900

35

2%

Case IH 3320

Non-AIM
Command
Mode PWM
12-volt

122

**700-
900

35

2%

Case IH 4420
with A-post

Non-AIM
Command
Mode PWM
12-volt

122

**700-
900

35

2%

Case IH 3200
(KZKCO Valve)

Non-AIM
Command
Mode By-Pass
Servo

2%

40%

10%

5

Case IH 4260
with Raven
valve

Non-AIM
Command
Mode By-Pass
Servo

2%

100%

24%

3

Case IH 4260
with KZKCO
valve

Non-AIM
Command
Mode By-Pass
Servo

2%

40%

10%

5