beautypg.com

HP 3PAR Operating System Software User Manual

Page 37

background image

The following information is provided:

Description

Field

Group

The location of the SFP within the system.

Position

General

Current condition of the SFP.

State

Manufacturer of the SFP.

Manufacturer

Part number of the SFP.

Part Number

Serial number of the SFP.

Serial Number

SFP's revision level.

Revision

Maximum speed allowed by the SFP.

Max Speed

Displays whether the SFP has been tested and if the SFP is supported.

Qualified

Displays whether the transmit laser is disabled.

TX Disable

Displays whether the transmit laser has a problem.

TX Fault

Displays whether the receive end of the SFP is experiencing a loss of
signal from the host or drive cage.

RX Loss

Displays whether the SFP receive power is low.

RX Power Low

Displays whether the SFP is DDM-capable (Digital Diagnostic
Monitoring).

DDM Support

Description

Column

Identifies the monitored parameters (temperature, voltage, TX bias, TX
power, and RX power).

Type

DDM

The unit of measure used for the monitored parameters.

Unit

The current measured value.

Value

The manufacturer's recommended lower-limit warning level.

Low Threshold Warning

The manufacturer's recommended upper-limit warning level.

High Threshold Warning

Viewing System Ports

37