Editing drive cages, Locating drive cages, Editing drive cage power supplies – HP 3PAR Operating System Software User Manual
Page 330
Description
Column
The last occurrence of the alert.
Last Time
A brief description of the alert.
Message
The number of times the alert has been issued.
Repeat Count
The first occurrence of the alert.
First Time
Editing Drive Cages
To edit a drive cage:
1.
In the Manager Pane, select Systems.
2.
In the Management Tree, select Drive Cages under the system with the drive cage you want
to edit.
3.
In the Summary tab of the list pane displayed in Management Window, right-click the drive
cage you want to edit and select Edit.
The Edit Cage Location dialog box appears.
4.
Enter the drive cage location the Location field.
5.
Click OK.
Locating Drive Cages
This operation locates a drive cage, or components of the drive cage such as drive magazines or
ports in the storage server, by setting the related LED(s) to amber or oscillate.
1.
In the Manager Pane, select Systems.
2.
In the Management Tree, select Drive Cages under the system with the drive cage you want
to locate.
3.
In the Summary tab of the list pane displayed in Management Window, right-click the drive
cage you want to locate and select Locate.
The Locate Cage dialog box appears.
To locate a magazine component, click the Magazine tab in the Drive Cage Details screen,
then right-click the magazine you want to locate. In this case the Locate Magazine dialog box
appears.
4.
In the Duration field, enter a value of 1 to 255 seconds. For EOS systems, the range is 1–3600
seconds, with a default duration of 900 seconds. For other systems prior to EOS, the range
is from 1 and 255 seconds, with a default of 60 seconds.
5.
In the Target Component list, select the cage, magazine, or port you want to locate. (The
subcomponents available depend on the HP 3PAR StoreServ Storage model.)
6.
Click OK.
When the Locate operation begins, a locate icon is displayed next to the selected node for the
duration specified. A detailed message will be displayed in the status bar and is updated when
the locate operation has completed. If a subcomponent was selected, the detail pane automatically
displays the tab associated with that subcomponent.
You can stop a Locate operation by selecting Stop Locate instead of Locate in Step
.
Editing Drive Cage Power Supplies
To edit a drive cage power supply:
1.
In the Manager Pane, select Systems.
2.
In the Management Tree, select Drive Cages under the system with the drive cage you want
to edit.
330 Managing Drive Cages