The following information is displayed in the detail pane:
Description
Field
Group
The port location in Node:Slot:Port format.
Position
General
The designated port label.
Label
Indicates whether the port is FC, iSCSI, RCIP, or
RCFC.
Type
Rate that data can be transferred over the port (1
Gbps, 2 Gbps or 4 Gbps). When there is no
specified value, no connection exists.
Rate
Type of device that the port is connected to. Free,
Disk, Host, Peer, or InServ.
Connected Device Type
Name of device that the port is connected to, for
example, host1, cage0.
Connected Device
Port firmware mode setting. Ports in Initiator mode
are connected to drive cages and ports in Target
Mode
mode export to hosts. Suspended mode is for target
ports that have not yet been initialized by the system
(rare). Peer mode is for Ethernet ports.
Current state of the port.
State
The MAC address for the Ethernet interface.
MAC
IP Settings
IP address of the RCIP port.
IP Address
The address of a local IP router on the same network
as the Storage System, used to forward traffic to
destinations beyond the local network.
Gateway
Netmask address for the RCIP interface.
Subnet Mask
The greatest amount of data or "packet" size that
can be transferred at one time over a particular
MTU
network connection without overburdening the
connection. The default MTU setting for an iSCSI port
is 1500. When supported by the network, an MTU
value of 9000 should be used.
The duplex speed, Half or Full.
Configured Rate
Model of the adapter that contains the port (for
example, Intel PRO/1000MT).
Duplex
The TCP port number used by the iSCSI or RCIP card.
Adapter Type
The throughput in KB/s.
Total Data Throughput
Resources
RCFC Tab
The RCFC tab displays a summary of all RCFC ports on a system.