Viewing drive cage alerts – HP 3PAR Operating System Software User Manual
Page 321
The following information appears in the detail pane:
Description
Field
Group
The position in the drive cage.
Cage
General
Interface card number, as assigned by the system.
Interface Card
SFP number, as assigned by the system.
SFP
Current condition of the SFP.
State
Manufacturer of the SFP.
Manufacturer
Part number of the SFP.
Part Number
Serial number of the SFP.
Serial Number
SFP's revision level.
Revision
Maximum speed allowed by the SFP.
Max Speed
Displays whether the SFP has been tested and if the SFP is
supported.
Qualified
Displays whether the transmit laser is disabled.
TX Disable
Displays whether the transmit laser has a problem.
TX Fault
Displays whether the receive end of the SFP is experiencing a loss
of signal from the host or drive cage.
RX Loss
Displays whether the SFP receive power is low.
RX Power Low
Displays whether the SFP is DDM-capable (Digital Diagnostic
Monitoring).
DDM Support
Description
Column
Identifies the monitored parameters (temperature, voltage, TX bias,
TX power, and RX power).
Type
DDM
The unit of measure used for the monitored parameters.
Unit
The current measured value.
Value
The manufacturer's recommended lower-limit warning level.
Low Threshold Warning
The manufacturer's recommended upper-limit warning level.
High Threshold Warning
The manufacturer's recommended lower-limit alarm level.
Low Alarm Threshold
The manufacturer's recommended upper-limit alarm level.
High Alarm Threshold
Viewing Drive Cage Alerts
To view the Drive Cage alerts:
1.
Navigate to the Drive Cages screen.
2.
In the list pane, click the Alerts tab.
The list pane of the Alerts tab displays summary alert information. The detail pane of the Alerts
tab displays detailed information about a selected alert from the list pane.
Viewing Drive Cages
321