Viewing the drive cage interface card details – HP 3PAR Operating System Software User Manual
Page 324
Description
Field
Group
The throughput in KB/s for the Loop B port.
Loop B
Revision of firmware running on the FC-AL for port A.
Loop A
Connectivity
Controller node initiator port connected to drive cage port A0.
A0 Port
Controller node initiator port connected to drive cage port A1.
A1 Port
Controller node initiator port connected to drive cage port A2.
A2 Port (for DC3 drive cages)
Controller node initiator port connected to drive cage port A3.
A3 Port (for DC3 drive cages)
Revision of firmware running on the FC-AL for port B.
Loop B
Controller node initiator port connected to drive cage port B0.
B0 Port
Controller node initiator port connected to drive cage port B1.
B1 Port
Controller node initiator port connected to drive cage port B2.
B2 Port (for DC3 drive cages)
Controller node initiator port connected to drive cage port B3.
B3 Port (for DC3 drive cages)
Displays if the selected drive cage is connected to another drive
cage, i.e. daisy chained.
Daisy Chained
Distance the drive cage is from the controller node port (0 = directly
connected to system ports, 1= there is one device between the node
and this drive cage, and so on).
Position A
Distance the drive cage is from the controller node port (0 = directly
connected to system ports, 1= there is one device between the node
and this drive cage, an so on).
Position B
Any alerts.
New Alerts
Health
Current state of the drive cage: Normal, Degraded, or Failed. See
“System and Component Status Icons” (page 506)
.
State
The temperature value of the drive cage.
Temperature Sensor Value (for
DC3 drive cages)
The firmware version on the drive cage.
Firmware (for DC2 and DC4
drive cages)
Description of the drive cage state.
State Description
Viewing the Drive Cage Interface Card Details
To view interface card details:
1.
Navigate to the Drive Cages screen.
2.
In the list pane of the Drive Cages screen, click the Summary tab and select a drive cage.
3.
In the detail pane, click the Interface Cards tab.
The Interface Cards tab appears as follows (the following depicts information for a DC2 drive
cage. Your screen might differ depending on the drive cage type in your system):
324 Managing Drive Cages